AC motor
Three-speedChoose a fixed speed step for the required duty. Check balance and available airflow at each usable step after the specified filter is installed.
AIROSEN modular fan filter units supply filtered air to cleanroom ceilings, process equipment and local clean zones. Select an FFU or EFU for your installation and control requirements.
Start with your mounting footprint and installation type. Open a product page to check fixing points, controls and service access before requesting a selection.
| Model & footprint | Details | Airflow m³/h | Air velocity m/s | External static pressure Pa | HEPA / ULPA grade | Filtration efficiency % | Motor type | Motor power W | Motor speed rpm | Noise level dB(A) | Voltage V | Housing material | Speed control | Application |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard FFU575 × 575 mm |
Details ↗ | —Specified per configuration | 0.45 ±20% | —Specified per configuration | —Specified per configuration | —Specified per configuration | AC / DC | —Specified per configuration | 0–1,400 DC | —Specified per configuration | —Specified per configuration | Al alloy / steel | AC 3-step / DC variable | Compact square ceiling modules and small clean zones. |
Standard FFU1175 × 575 mm |
Details ↗ | —Specified per configuration | 0.45 ±20% | —Specified per configuration | —Specified per configuration | —Specified per configuration | AC / DC | —Specified per configuration | 0–1,400 DC | —Specified per configuration | —Specified per configuration | Al alloy / steel | AC 3-step / DC variable | Rectangular ceiling bays for new fit-outs or replacement projects. |
Standard FFU1175 × 1175 mm |
Details ↗ | —Specified per configuration | 0.45 ±20% | —Specified per configuration | —Specified per configuration | —Specified per configuration | AC / DC | —Specified per configuration | 0–1,400 DC | —Specified per configuration | —Specified per configuration | Al alloy / steel | AC 3-step / DC variable | Large square ceiling bays with matching grid support. |
EFU575 × 575 mm |
Details ↗ | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | Compact machine enclosures and localized clean zones. |
EFU1175 × 575 mm |
Details ↗ | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | Rectangular mounting openings in process equipment. |
Dual-fan FFU1175 × 575 mm |
Details ↗ | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | Dual-fan layouts where the project calls for two fans in one housing. |
Explosion-proof FFU1175 × 575 mm · Project review |
Details ↗ | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | —Specified per configuration | Hazardous-area enquiries that require review of the complete unit and its approval documents. |
No configurations match. Select another type or footprint.
Specify the final filter as part of the complete fan filter unit. Filter efficiency, initial resistance and the housing seal all affect the air delivered to the clean zone.
Explore HEPA terminal housings ↗The FFU fan is designed for low-noise, low-vibration operation, adjustable speed and maintenance-free fan operation. Plan separate inspections for filters, seals and the rest of the assembly.
Choose a fixed speed step for the required duty. Check balance and available airflow at each usable step after the specified filter is installed.
Use adjustable speed to set the operating point. Confirm the command interface, minimum working speed and selected fan curve in the project submittal.
Digital adjustment and centralized computer control support grouped operation. Specify grouping, setpoints, monitoring and alarm behavior early in the project.
Air enters at the top. The fan moves it through the configured filtration stages and across the outlet face, distributing filtered air into the clean zone.

Match the FFU housing to the grid load, cleaning chemistry, humidity and surface finish required by the project.
Combine ceiling-mounted FFUs for room coverage or integrate an EFU for local air delivery. Plan each installation around the process and return-air path.

Coordinate an FFU ceiling array with process-tool locations and returns. Use an EFU for localized delivery in equipment enclosures.
Check filter integrity access, cleanable housing surfaces and airflow around exposed product against the qualified process design.
Cover inspection, assembly and packaging points. Coordinate fan control and service access with automation and shift schedules.
Lay out filtration over assembly or packaging workstations. Confirm maintenance access and acceptance testing for the installed zone.
Use a compact FFU for local product protection. Confirm the bench airflow pattern and keep containment requirements in the facility design.
Divide a clean production line into serviceable zones and size the ceiling grid and return paths for future bays.
Typical applications include cleanroom environments from Class 100 to Class 100,000, including Class 100 assembly lines subject to project design. Specify and verify the required room classification on the completed installation.
Send a drawing and duty point to review dimensions, airflow, filter fit, motor options, housing and control together before specifying a non-standard assembly.
Discuss your project ↗Use the room or tool design to set the duty point, then compare supplier selections with the same filter and external resistance.
Measure the clear opening, height above the grid and lift route. Check support capacity, air intake clearance and room-side or ceiling-side service.
For a discharge face, Q = 3,600 × average face velocity (m/s) × effective area (m²). For an air-change design, multiply the specified air changes per hour by room volume (m³) to obtain the design flow in m³/h. Check the applicable coverage and pressure balance separately.
Start with the process specification. Check the grade, efficiency data, seal interface, and both initial and specified final resistance before sizing the fan.
Use the selected assembly’s fan curve to verify airflow at external static pressure with the filter installed. Confirm which losses the curve includes so they are counted once.
Compare a suitable AC step with DC speed adjustment at the required duty. Specify power supply, control method, grouping, alarms and acceptable sound pressure.
Divide required FFU airflow by the verified per-unit flow at the design duty point for a starting count, rounding up. Check ceiling coverage, return paths and the commissioning design before fixing the quantity.
Both combine a fan and filtration in an assembly. The main purchasing difference is the interface with the ceiling or the process equipment.
AIROSEN supplies cleanroom equipment for engineering teams, equipment manufacturers, contractors and distributors. For FFU procurement, tie the selected assembly to its drawings, controls and agreed inspection documents.

A fan filter unit is a self-contained module with a powered fan and high-efficiency filtration. A cleanroom FFU typically mounts in a ceiling grid or over a local clean zone to supply filtered air.
The fan draws air from the top, moves it through any fitted pre-filter and the selected final filter, then distributes it across the outlet face. The room return path or equipment enclosure completes the airflow design.
An FFU commonly serves a ceiling or work zone. An EFU is an equipment fan filter unit selected around a process tool’s mounting opening, internal airflow, electrical signals and service access.
The nominal outlet face velocity is 0.45 m/s ±20%. Confirm the value with the selected filter at the required duty point. Airflow in m³/h also depends on the effective discharge area.
The fan has a stated service life of more than 50,000 operating hours. Confirm the operating conditions for the selected assembly and use the site’s maintenance plan for the filter and seals.
The AC motor offers three speed settings, while the DC motor supports adjustable speed from 0 to 1,400 rpm. Confirm the control interface and usable operating range for the selected configuration.
Multiple FFUs can be integrated for centralized computer control where the compatible control configuration is selected. Specify which units form a zone, the speed commands and any status or alarms the system needs.
Check the ceiling opening, required airflow at static pressure, filter grade, power supply and service access. Then verify unit count and placement with the cleanroom designer.
Submit the required dimensions, filter grade and duty point for a project review. The approved combination depends on housing depth, mounting interface, filter resistance, motor and controls.
Set replacement criteria from filter pressure drop, measured airflow, integrity test results and your maintenance plan. Check the installed filter after replacement using the project’s agreed method.
Send AIROSEN your project requirements for configuration review and pricing. Attach a ceiling layout, equipment drawing or existing unit nameplate if available.