Air filtration
Cleanroom equipment for controlled environments.
AIROSEN supplies fan filter units and HEPA terminal housings for cleanroom ceilings, equipment zones and ducted air supply.
Explore air filtration
Air filtration
AIROSEN supplies fan filter units and HEPA terminal housings for cleanroom ceilings, equipment zones and ducted air supply.
Explore air filtration ↗
Access & transfer
Source personnel and cargo air showers, cleanroom doors and interlocked pass boxes matched to your room openings and traffic routes.
Explore access equipment ↗
Hygiene & storage
Specify stainless steel scrub sinks, garment and shoe cabinets, worktables and trolleys around your gowning, preparation and cleaning routines.
Explore hygiene equipment ↗AIROSEN / SPECIALIST EQUIPMENT SUPPLY
Source filtration units, air showers, pass boxes, cleanroom doors and hygiene equipment through one coordinated supply partner. Equipment and supporting facilities for the way your cleanroom operates.
Air filtration Personnel & cargo access Material transfer Hygiene & storage

Fan-powered filtration for cleanroom ceilings and local clean-air zones. Standard, equipment-use, dual-fan and explosion-proof configurations.
Product details ↗
Terminal filter housings for cleanroom air supply. Top-entry, side-entry and gel-seal arrangements for ceiling and duct interfaces.
Product details ↗
Personnel entry equipment for removing loose particles from garments. Enclosure and door layouts coordinated with the gowning route.
Product details ↗
Larger air shower chambers for goods, trolleys and equipment. Door configurations selected around the load and handling route.
Product details ↗
Interlocked chambers for material transfer between rooms. Static, air-shower and laminar-flow configurations for different operating requirements.
Product details ↗
Stainless-steel hand-washing and surgical scrub stations. Single, double and multiple-user arrangements for hygiene and preparation areas.
Product details ↗
Clean garment storage for gowning areas. Filtered, laminar-flow and compartment arrangements to suit garment handling and room layout.
Product details ↗
Shoe cabinets, lockers and step-over benches for changing areas. Open and enclosed storage coordinated with the gowning sequence.
Product details ↗
High-speed roll-up doors for frequent personnel and goods movement. Clear opening, curtain and control options matched to the access route.
Product details ↗
Automatic sliding doors for controlled-area access. Opening dimensions, side clearance and activation interfaces coordinated with the room layout.
Product details ↗
Work tables, inspection benches, trolleys and shelving for cleanroom use. Dimensions, working loads and finishes matched to daily operation.
Product details ↗Connect product selection, configuration, dimensions and delivery requirements in one equipment schedule.
Equipment selection guide ↗INDUSTRIAL APPLICATIONS
From electronics to food and medical production, AIROSEN supplies the filtration, entry, transfer and hygiene equipment that supports daily cleanroom operation.

Electronics Manufacturing
Electronics assembly combines particle-sensitive surfaces, personnel movement and equipment-generated heat. The cleanroom equipment schedule should follow the production layout and the points where people and materials cross into controlled areas.
Coordinate FFU positions with process obstructions and service access. Review material transfer frequency, pass-box chamber sizes and air-shower entry routes alongside the room airflow strategy.

Semiconductor Industry
Semiconductor-related production calls for carefully specified filtration, personnel access and material-transfer equipment. AIROSEN coordinates these supporting facilities with the room layout and process requirements supplied by the project team.
Review FFU duty, terminal filter sealing and testing access with the room designer. Select transfer equipment for the actual object envelope and room relationship. Match dimensions, filtration, controls and maintenance access to the project equipment schedule.

Food Processing
Food processing and packaging layouts depend on hygiene zoning, operator movement and cleaning routines. Equipment should support the separation of routes while remaining accessible for regular inspection, washing and maintenance.
Specify sink station counts, activation methods and drainage positions. Review door operation against trolley movement and cleaning practices. Define the stainless-steel grade and surface finish for furniture rather than assuming one material specification suits every area.

Medical & Pharma
Medical-device and pharmaceutical facilities require the transfer and gowning strategy to reflect the intended process and the relationship between adjacent rooms. Equipment configurations should be reviewed with the project contamination-control and cleaning requirements.
Agree pass-box airflow and operating sequences, chamber cleanability and door interlocks before fabrication. Coordinate cabinet filtration, hand hygiene and maintenance access. Prepare the required equipment documentation and inspection scope with the customer.

Battery & New Energy
Battery and new-energy production can combine frequent material movement with process-specific environmental targets. Entry equipment, transfer chambers and air delivery must fit the handling route without obstructing production or maintenance.
Record maximum loads, door clearances, transfer frequency and control interfaces. Match the equipment configuration, finishes and service connections to the project team’s environmental brief.

Plastics & Packaging
Packaging and plastics production can involve high-frequency movement of people, packaging stock and finished goods. The equipment arrangement should follow the production rate and hygiene zoning rather than treating every doorway as the same interface.
Check opening dimensions, activation and safety interfaces against daily traffic. Locate pass boxes and storage furniture where they reduce unnecessary room entry. Coordinate the supply dimensions and service connections with the installation drawings.

Automotive & Precision
Precision assembly, inspection and component handling may require local controlled areas within a larger factory. Define the process boundary, the parts being handled and the operator routine before selecting the cleanroom equipment package.
Coordinate FFUs and HEPA supply points with equipment height and maintenance space. Select transfer chambers and trolleys for part dimensions and working loads. Define the required cleanliness target and verification method with the responsible process team.
PROJECT CASES
Cleanroom supporting facilities for electronics production, food processing and medical environments. Explore the equipment priorities behind each setting.
VietnamAir filtration & controlled transfer
Particle-sensitive assembly, controlled personnel entry and small-component transfer across the production boundary.
Fan filter units · HEPA housings · Personnel air showers · Pass boxes
ThailandHygiene & production access
Hygiene facilities, cleanable work areas and access equipment arranged around daily processing and packaging routes.
Hand-washing sinks · Cargo air showers · High-speed doors · Stainless furniture
KazakhstanClinical preparation & clean storage
Hand hygiene, clean storage and room-access equipment coordinated around clinical preparation and staff movement.
Surgical scrub sinks · Automatic sliding doors · Storage cabinets · Transfer hatches
SUPPLY SOLUTIONS
Bring filtration, personnel access, material transfer and hygiene equipment into one supply package. Each product is selected against the room drawings, workflow and technical requirements provided by your project team.
Coordinate FFUs and HEPA terminal diffusers with the ceiling grid, room airflow strategy and filter maintenance route. Define air volume, power, control and duct connections before equipment selection.
Arrange hand hygiene, garment storage, footwear change and the personnel air shower as a usable entry sequence. Check occupancy, movement direction and clear openings against the room layout.
Separate small-item transfers from pallet and trolley movement. Select pass boxes, cargo air showers and access doors around load dimensions, handling equipment and the adjacent room conditions.
Prepare a coordinated equipment schedule from your room layout. Align product dimensions, mounting requirements, service connections and delivery priorities before supply.
Replace or add air showers, transfer equipment, doors and gowning facilities around existing openings, utilities and operating routes.


WHY AIROSEN
AIROSEN specialises in cleanroom equipment and supporting facilities, bringing the essential products for air filtration, access, transfer and hygiene into one coordinated supply scope.
Our range covers fan filter units, HEPA terminal housings, personnel and cargo air showers, pass boxes, cleanroom doors, washing stations, cabinets and stainless-steel furniture. We connect the required product configurations with your room layout and operating routes.
From product dimensions and service connections to packing and identification, the supply package follows an agreed equipment schedule. Technical clarification and remote guidance support customers and local installers, with a regional focus on Southeast Asia and Central Asia.

ENGINEERING OUR NEXT CHAPTER
Equipment knowledge, an expanding product range and coordinated supply support the way we serve cleanroom projects today.
Factory air treatment and controlled production environments establish the technical starting point.
Cleanroom equipment, supporting components and installation materials come into one supply scope.
Equipment schedules and room interfaces connect product selection with the project brief.
Regional adaptation and remote technical guidance support overseas customers and local teams.
QUALITY DOCUMENTATION
Equipment specifications, agreed inspection records and supporting documents are organised around your supply scope.
Configurations, materials and performance requirements.
Approved dimensions, interfaces and operating information.
Product references and delivery information for your order.

FROM PRODUCT BRIEF TO EQUIPMENT DELIVERY
Product selection, technical confirmation and delivery documentation keep your equipment supply aligned with the project team.
Review the required product families, quantities, room openings, traffic routes and utility conditions.
Agree equipment configurations, dimensions, openings, connection positions and delivery identification.
Provide agreed remote guidance for installation questions, service access, room interfaces and site connections.
Align start-up guidance, troubleshooting, maintenance advice and handover information with the supplied equipment.
TECHNICAL DESIGN REVIEW
Cleanroom equipment must fit the air system, room construction and operating procedure. Resolve these points before freezing dimensions and approving the equipment schedule.
Review the required air volume against fan performance and the resistance of the specified filter arrangement. Define the operating point, control method, electrical supply and maintenance side. Allow for the agreed filter condition rather than selecting by enclosure size alone.
Air volume · filter resistance · power and controls · ceiling loading · replacement clearance
Coordinate filter dimensions, sealing arrangement, duct entry and the ceiling connection. Confirm how the installed filter and its seals will be accessed, tested and replaced without obstructing adjacent services.
Inlet direction · gasket or gel seal · test access · support detail · room-side service route
Define the material envelope, transfer frequency and adjacent room conditions before choosing a static or filtered-air chamber. Agree interlock behaviour, cleaning access and any airflow sequence required by the contamination-control strategy.
Load size · door interlock · transfer direction · cleaning method · utilities and controls
Separate personnel and goods routes where the layout requires it. Check door clear openings against actual trolley or pallet dimensions; review air-shower entry and exit arrangements, safety interfaces and bypass provisions with the project team. Specify stainless-steel grade, finish and cleaning compatibility for sinks, cabinets and furniture.
Clear opening · wall thickness · drainage · activation method · material finish · maintenance space
CONFIGURATION ESSENTIALS
Share the equipment type, quantities, dimensions and operating conditions. We use these inputs to organise the supporting facilities your cleanroom needs.
FFU / EFU · HEPA terminal housings
Standard or dual-fan units; top-entry, side-entry and gel-seal housings.
Air volume · filter resistance · ceiling grid · service accessPersonnel & cargo air showers · cleanroom doors
Personnel and cargo layouts; hinged, sliding or high-speed door arrangements.
Traffic route · clear opening · interlocks · safety interfacesPass boxes & transfer hatches
Static, air-shower and laminar-flow chambers, selected for the transfer process.
Load envelope · adjacent rooms · airflow sequence · cleaning accessSinks · garment & shoe cabinets · stainless furniture
Washing, gowning and storage layouts coordinated around daily operation.
User capacity · dimensions · material finish · water & drainageTECHNICAL QUESTIONS
Short explanations of the distinctions that matter when planning cleanroom equipment.
An FFU includes a fan and filter in one unit for local filtered-air delivery. A HEPA diffuser is a terminal filter housing and distribution outlet connected to an air supply system. Select either with the room airflow strategy, ceiling layout and maintenance route.
A static pass box provides an interlocked chamber. Air shower and laminar-flow pass boxes add filtered airflow where the transfer process calls for it. The material, adjacent room conditions and contamination-control plan determine the appropriate arrangement.
Personnel air showers are arranged around people entering a controlled space. Cargo air showers need a larger clear opening and a route suitable for trolleys, pallets or other handling equipment. Specify load dimensions and door operation before selecting either type.
Our supporting equipment includes clean garment cabinets, shoe cabinets, step-over benches and hand-washing or scrub sinks. The changing sequence, number of users, storage capacity and cleaning routine guide the layout.
Send the product types and quantities, room layout or opening dimensions, material and finish requirements, utility conditions and destination. For FFUs and HEPA housings, include the required airflow and filter arrangement; for access and transfer equipment, include the traffic route and maximum load size.
Whether you are planning a new production facility or selecting equipment for an existing project, tell us what you need. We can discuss the air treatment and cooling requirements for your application.