Fan Filter Unit (FFU)

AIROSEN modular fan filter units supply filtered air to cleanroom ceilings, process equipment and local clean zones. Select an FFU or EFU for your installation and control requirements.

575 × 575 mm standard fan filter unit with top fan inlet and handling grips 1175 × 575 mm dual-fan FFU with two fan inlets

AIROSEN FFU at a glance

0.45 m/s ±20%
Nominal outlet face velocity
50,000+ hours
Documented fan service life
AC / DC
Motor and speed-control options
Individual or multi-unit installation Particle-count scanning before shipment Aluminum alloy, stainless steel and steel housings

Fan Filter Units Product Range

Start with your mounting footprint and installation type. Open a product page to check fixing points, controls and service access before requesting a selection.

Model & footprint Details Airflow m³/h Air velocity m/s External static pressure Pa HEPA / ULPA grade Filtration efficiency % Motor type Motor power W Motor speed rpm Noise level dB(A) Voltage V Housing material Speed control Application
575 × 575 mm Fan Filter Unit with top fan inletStandard FFU575 × 575 mm Details Specified per configuration 0.45 ±20% Specified per configuration Specified per configuration Specified per configuration AC / DC Specified per configuration 0–1,400 DC Specified per configuration Specified per configuration Al alloy / steel AC 3-step / DC variable Compact square ceiling modules and small clean zones.
1175 × 575 mm Fan Filter Unit with top fan inletStandard FFU1175 × 575 mm Details Specified per configuration 0.45 ±20% Specified per configuration Specified per configuration Specified per configuration AC / DC Specified per configuration 0–1,400 DC Specified per configuration Specified per configuration Al alloy / steel AC 3-step / DC variable Rectangular ceiling bays for new fit-outs or replacement projects.
1175 × 1175 mm Fan Filter Unit with top fan inletStandard FFU1175 × 1175 mm Details Specified per configuration 0.45 ±20% Specified per configuration Specified per configuration Specified per configuration AC / DC Specified per configuration 0–1,400 DC Specified per configuration Specified per configuration Al alloy / steel AC 3-step / DC variable Large square ceiling bays with matching grid support.
575 × 575 mm EFU with equipment mounting housingEFU575 × 575 mm Details Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Compact machine enclosures and localized clean zones.
1175 × 575 mm EFU with equipment mounting housingEFU1175 × 575 mm Details Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Rectangular mounting openings in process equipment.
1175 × 575 mm Dual-Fan FFU with two fan inletsDual-fan FFU1175 × 575 mm Details Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Dual-fan layouts where the project calls for two fans in one housing.
1175 × 575 mm Explosion-Proof FFU with enclosed electrical connectionExplosion-proof FFU1175 × 575 mm · Project review Details Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Specified per configuration Hazardous-area enquiries that require review of the complete unit and its approval documents.

HEPA & ULPA filtration selection

Specify the final filter as part of the complete fan filter unit. Filter efficiency, initial resistance and the housing seal all affect the air delivered to the clean zone.

Explore HEPA terminal housings
Pre-filter
Where the layout includes a pre-filter, place it upstream of the final stage to intercept coarse particles. Include its resistance and service clearance in the selection.
HEPA or ULPA
Choose the grade in the project specification. Compare efficiency at the stated test particle size, along with resistance at the same airflow. For ULPA requirements, request an engineering review of the filter frame, pressure budget and fan selection.
Filter sealing and replacement
Check the seal interface on the assembly drawing. Decide whether the service route must be from the room or the ceiling void, and agree the filter integrity checks after installation or replacement.

Fan motor and intelligent control

The FFU fan is designed for low-noise, low-vibration operation, adjustable speed and maintenance-free fan operation. Plan separate inspections for filters, seals and the rest of the assembly.

AC motor

Three-speed

Choose a fixed speed step for the required duty. Check balance and available airflow at each usable step after the specified filter is installed.

DC motor

0–1,400 rpm

Use adjustable speed to set the operating point. Confirm the command interface, minimum working speed and selected fan curve in the project submittal.

Multi-unit control

Local or central

Digital adjustment and centralized computer control support grouped operation. Specify grouping, setpoints, monitoring and alarm behavior early in the project.

Uniform airflow performance

Air enters at the top. The fan moves it through the configured filtration stages and across the outlet face, distributing filtered air into the clean zone.

  1. Top air intakeFan draws air from above
  2. Pre-filtrationWhen fitted
  3. Final filtrationHEPA or specified filter stage
  4. Uniform dischargeAcross the outlet face
0.45 m/s ±20%Nominal outlet face velocity. For volumetric airflow in m³/h, use the effective discharge area and the actual duty point.
Technician working on a sheet-metal equipment panel in the manufacturing workshop

Housing materials and construction

Match the FFU housing to the grid load, cleaning chemistry, humidity and surface finish required by the project.

Aluminum alloy
Lightweight construction where handling and grid load matter.
Stainless steel
Durable, corrosion-resistant construction for frequent cleaning. Confirm the alloy and finish.
Aluminum-zinc-coated steel
A coated steel option that balances stiffness with corrosion and rust resistance.
Cold-rolled steel
A rigid housing option. Specify the protective finish for the operating environment.

Fan filter unit applications

Combine ceiling-mounted FFUs for room coverage or integrate an EFU for local air delivery. Plan each installation around the process and return-air path.

Gowned cleanroom operator working beside enclosed production equipment

Semiconductor cleanrooms

Coordinate an FFU ceiling array with process-tool locations and returns. Use an EFU for localized delivery in equipment enclosures.

Pharmaceutical cleanrooms

Check filter integrity access, cleanable housing surfaces and airflow around exposed product against the qualified process design.

Electronics manufacturing

Cover inspection, assembly and packaging points. Coordinate fan control and service access with automation and shift schedules.

Medical device manufacturing

Lay out filtration over assembly or packaging workstations. Confirm maintenance access and acceptance testing for the installed zone.

Laboratories and clean benches

Use a compact FFU for local product protection. Confirm the bench airflow pattern and keep containment requirements in the facility design.

Modular cleanrooms and production lines

Divide a clean production line into serviceable zones and size the ceiling grid and return paths for future bays.

Typical applications include cleanroom environments from Class 100 to Class 100,000, including Class 100 assembly lines subject to project design. Specify and verify the required room classification on the completed installation.

Custom FFU configuration

Send a drawing and duty point to review dimensions, airflow, filter fit, motor options, housing and control together before specifying a non-standard assembly.

Discuss your project
Fit and service
Review length, width, height, mounting points, service side, filter removal clearance and housing finish.
Filtration and motor
Match the specified grade, seal and filter resistance to AC or DC selection, airflow and external static pressure.
Digital and centralized control
Define individual settings, grouped speed commands and the connection to the site’s controls. Share the required signals before the configuration is finalized.

How to select a cleanroom FFU

Use the room or tool design to set the duty point, then compare supplier selections with the same filter and external resistance.

  1. Size the installation

    Measure the clear opening, height above the grid and lift route. Check support capacity, air intake clearance and room-side or ceiling-side service.

  2. Calculate the airflow

    For a discharge face, Q = 3,600 × average face velocity (m/s) × effective area (m²). For an air-change design, multiply the specified air changes per hour by room volume (m³) to obtain the design flow in m³/h. Check the applicable coverage and pressure balance separately.

  3. Choose HEPA or ULPA filtration

    Start with the process specification. Check the grade, efficiency data, seal interface, and both initial and specified final resistance before sizing the fan.

  4. Evaluate static pressure

    Use the selected assembly’s fan curve to verify airflow at external static pressure with the filter installed. Confirm which losses the curve includes so they are counted once.

  5. Select the motor and controls

    Compare a suitable AC step with DC speed adjustment at the required duty. Specify power supply, control method, grouping, alarms and acceptable sound pressure.

  6. Determine unit count

    Divide required FFU airflow by the verified per-unit flow at the design duty point for a starting count, rounding up. Check ceiling coverage, return paths and the commissioning design before fixing the quantity.

FFU vs. EFU

Both combine a fan and filtration in an assembly. The main purchasing difference is the interface with the ceiling or the process equipment.

Fan filter unit (FFU)
Typically mounts in a cleanroom ceiling grid over a room or work zone. Coordinate ceiling support, air distribution, replacement access and grouped controls.
Equipment fan filter unit (EFU)
Mounts to an equipment enclosure or defined process opening. Coordinate equipment mounting, cable routes, machine signals and local filtered airflow.
Ducted HEPA terminal housing
Receives airflow from upstream HVAC equipment. Check the duct connection, balanced volume and available pressure at the terminal.

Manufacturing and quality assurance

AIROSEN supplies cleanroom equipment for engineering teams, equipment manufacturers, contractors and distributors. For FFU procurement, tie the selected assembly to its drawings, controls and agreed inspection documents.

Laser cutting machine and operator working in a sheet-metal fabrication workshop
Assembly scope
Review the housing, fan mounting and filter seat together. Confirm which parts ship with the unit and which are supplied or fitted on site.
Individual particle-count scanning
The product documentation specifies particle-counter scanning of each FFU before shipment. Request the applicable method and acceptance criteria with your order. Define installed filter and room tests separately.
Technical documentation
Request the product datasheet, configuration details, installation drawing, applicable inspection records and any project-specific approvals. Identify the assembly and destination market on the enquiry.
Request technical documents

Fan filter unit FAQ

What is a fan filter unit?

A fan filter unit is a self-contained module with a powered fan and high-efficiency filtration. A cleanroom FFU typically mounts in a ceiling grid or over a local clean zone to supply filtered air.

How does a fan filter unit work?

The fan draws air from the top, moves it through any fitted pre-filter and the selected final filter, then distributes it across the outlet face. The room return path or equipment enclosure completes the airflow design.

What is the difference between an FFU and an EFU?

An FFU commonly serves a ceiling or work zone. An EFU is an equipment fan filter unit selected around a process tool’s mounting opening, internal airflow, electrical signals and service access.

What air velocity does an FFU provide?

The nominal outlet face velocity is 0.45 m/s ±20%. Confirm the value with the selected filter at the required duty point. Airflow in m³/h also depends on the effective discharge area.

How long does an FFU fan last?

The fan has a stated service life of more than 50,000 operating hours. Confirm the operating conditions for the selected assembly and use the site’s maintenance plan for the filter and seals.

How do AC and DC FFU motors differ?

The AC motor offers three speed settings, while the DC motor supports adjustable speed from 0 to 1,400 rpm. Confirm the control interface and usable operating range for the selected configuration.

Can multiple FFUs be controlled together?

Multiple FFUs can be integrated for centralized computer control where the compatible control configuration is selected. Specify which units form a zone, the speed commands and any status or alarms the system needs.

How do I select the right FFU for a cleanroom?

Check the ceiling opening, required airflow at static pressure, filter grade, power supply and service access. Then verify unit count and placement with the cleanroom designer.

Can FFU dimensions and filter configurations be customized?

Submit the required dimensions, filter grade and duty point for a project review. The approved combination depends on housing depth, mounting interface, filter resistance, motor and controls.

How often should an FFU filter be replaced?

Set replacement criteria from filter pressure drop, measured airflow, integrity test results and your maintenance plan. Check the installed filter after replacement using the project’s agreed method.

Request a fan filter unit quote

Send AIROSEN your project requirements for configuration review and pricing. Attach a ceiling layout, equipment drawing or existing unit nameplate if available.

Request a Quote